Classification : Industrial automation products
Country: Taiwan
Phone: 886-3-5553111
Fax: 886-3-5555339
Contact Person: Yvonne
Product feature:
Industrial RFID induction module, portable weight level information card, can achieve multi-weight level data function management;
Advantages: support panel integration and external independent installation (old machine can also be modified), use of one card and multiple machines, unified management of data permissions.
Specifications:
External independent installation size/H*W*D(mm) |
100*86*22 |
Read and write protocol (Standards) |
ISO15693 |
Chip type (IC Type) |
I-CODE-2 (I-CODE-SLI ) |
Reading distance (Distances) |
2.5~5cm |
Reading and writing speed (Response time) |
0.4s |
Communication interface (Communication) |
RS232 |
Power Supply (Switch Power Supply) |
5V |
Overview: this stage more the quality of the product requirements and hard plastic and mold, its smooth production must rely on the surrounding equipment, including mechanical arm, hot water in the controller, a valve gate controller, membrane labeling, die instant heating system, etc., the auxiliary machine, injection molding machine and mold is forming a production unit, relationship to the owners of production performance.
Purpose: mainly used for mold heating control of injection molding machine
Multi-mode cavitation heat channel controller
Product feature:
1. PID self-learning of temperature; 2. Support heater damage test; 3. Support balanced heating of all temperature segments; 4. Support temperature curve function; 5. Support automatic detection of whether thermocouple and heating output point are corresponding; 6. Have dehumidification function; 7. Perfect alarm function.
Multi-mode cavitation
![]() |
Specifications | |
Items | Specifications | |
Power Input | Three-phase five-wire AC380-415V/Three-phase four-wire AC200-240V | |
Control Module | AC85-265V | |
Supply Frequency | 50/60HZ automatic switching | |
HMI | 12 inches color touch screen | |
Thermocouple Type | J/K/E etc. thermocouple | |
Measurement Accuracy | ±0.25%F.S. | |
Control Accuravy |
±0.5℃ |
|
Control Mode |
closed loop(Auto),open loop(manual) |
|
Teperature Control Range | 0~450℃ (32-842 | |
Ouput Range | Adjust voltage by change breakover phase angle or adjust power at regular time | |
Rated Load | 16A every piece | |
Power Protection | overvoltage protection module | |
Input Protection | Software diagnose inversely connect, open circuit,dislocation; Semiconductor fuse | |
Output Protection |
Software diagnose inversely connect, open circuit,dislocation; Semiconductor fuse |
|
Alarm Method | Lights flashing, alarm code hinting, buzzer warning | |
Operating Environment | 0·50℃ (32-122),20-90%RH, no condensation of moisture |
Standard hot runner controller
![]() |
Specifications | |
Items | Specifications | |
Power Input | Three-phase five-wire AC380-415V/Three-phase four-wire AC200-240V | |
Control Module | AC85-265V | |
Supply Frequency | 50/60HZ automatic switching | |
HMI | Color touch screen | |
Thermocouple Type | J/K/E etc. thermocouple | |
Measurement Accuracy | ±0.25%F.S. | |
Control Accuravy |
±0.5℃ |
|
Control Mode |
closed loop(Auto),open loop(manual) |
|
Teperature Control Range | 0~450℃ (32-842 | |
Ouput Range | Adjust voltage by change breakover phase angle or adjust power at regular time | |
Rated Load | 16A every piece | |
Power Protection | overvoltage protection module | |
Input Protection | Software diagnose inversely connect, open circuit,dislocation; Semiconductor fuse | |
Output Protection |
Software diagnose inversely connect, open circuit,dislocation; Semiconductor fuse |
|
Alarm Method | Lights flashing, alarm code hinting, buzzer warning | |
Operating Environment | 0·50℃ (32-122),20-90%RH, no condensation of moisture |
Overview:
In the design of modern systems and machines, in addition to machine productivity and efficiency, safety issues have become increasingly important. Safety relays have made a decisive contribution to occupational safety during machine manufacturing and operation.
Security isolation
Anti - shock, anti - dust, anti - static
Anti - magnetic, high current load capacity
Single/double channel wiring
Manual/automatic reset
Advantages:
1. Suitable for machine safety protection;
2. High selectivity and flexibility of operation mode;
3. Multiple LED lights can be used for timely diagnosis.
Specification |
|
Model | SAFFsimple s4 |
Size(mm) | 99.8*22.5*113.6 |
Characteristic |
|
|
3NO+1NC |