Classification : Dynisco / Melt Pressure Transmitters
Country: Taiwan
Phone: 886-4-2631-3001
Fax: 886-4-2631-7717
Contact Person: Harrison Chang
All models can interface directly with distributed control systems, PLC’s, computers, and similar high level control devices. Optional thermocouple or RTD configurations are available to provide melt temperature.
The SPX4 Series includes models SPX4222, SPX4622, SPX4352, SPX4672, SPX4232, and SPX4502.
Performance Characteristics | |
Output | 4 - 20 mA, with optional HART™ |
Input Voltage | 16 - 36 Vdc (Std); 16 - 30 Vdc (ATEX IS) |
Accuracy | 4222 ± 0.25% for pressure ranges >1,500 psi; ± 0.50% for pressure ranges < 1,500 psi 4232 ± 0.25% for pressure ranges >1,500 psi; ± 0.50% for pressure ranges < 1,500 psi 4352 ± 0.25% for pressure ranges > 1,500 psi; ± 0.50% for pressure ranges < 1,500 psi 4502 ± 0.50% 4622 ± 0.50% 4672 ± 0.50% |
Repeatability | ±0.1% |
Rangeability | 6:1 Turndown |
Over Pressure | 2X FSO or 35,000 psi,whichever is less 1.2 X FSO 35,000 - 72,500 psi |
Zero Balance Adjustment Range | (-)40% to +10%;(-)80% to 20% for FSP < 500 psi |
Load Resistance | 500 Ω @ 24 Vdc, 1,000 Ω @ 36 Vdc |
Electronics Ambient Temperature | 70°F (20°C) |
Electronics Operating Temperature | -20 to 185°F (-29 to 85°C) |
Diaphragm Temperature | 750°F (400°C) max [SPX4502 model limited to 600°F (315°C)] |
Electronics Compenstated Temperature Range | 0 to 150°F (-18 to 65°C) |
Zero Shift (Electronics Temp Change) | 4222: 0.01% F.S./°F max (0.02% F.S./°C max) 4232: 0.01% F.S./°F max (0.02% F.S./°C max) 4352: 0.01% F.S./°F max (0.02% F.S./°C max) 4502: 0.01% F.S./°F max (0.02% F.S./°C max) 4622: 0.05% F.S./°F max (0.10% F.S./°C max) 4672: 0.05% F.S./°F max (0.10% F.S./°C max) |
Span Shift (Electronics Temp Change) | 4222: 0.01% F.S./°F max (0.02% F.S./°C max) 4232: 0.01% F.S./°F max (0.02% F.S./°C max) 4352: 0.01% F.S./°F max (0.02% F.S./°C max) 4502: 0.01% F.S./°F max (0.02% F.S./°C max) 4622: 0.02% F.S./°F max (0.04% F.S./°C max) 4672: 0.02% F.S./°F max (0.04% F.S./°C max) |
Zero Shift (Snout Temp Change) | 4222: 15 psi/100°F (27 psi/100°C) typical 4232: 15 psi/100°F (27 psi/100°C) typical 4352: 15 psi/100°F (27 psi/100°C) typical 4502: 1 psi/100°F (from 75-450°F); 2 psi/100°F (from 450-600°F) typical 4622: 25 psi/100°F (45 psi/100°C) typical 4672: 25 psi/100°F (45 psi/100°C) typical |